Condensate recovery unit
CONDENSATE RECOVERY UNIT
TYPE: WZZ
Capacity: Q=3-15m?/h Tanks: V=2-8m3
CLICK ON IMAGE TO ZOOM
CLICK ON IMAGE TO ZOOM
1. Application range
Standard version
Condensate recovery unit capacity: Q= 3 - 15 m3/h
Tank capacity: V = 2-8 m3/
Because of the large range of possibilities when using the pressure reduction station its operating range will always be agreed with the client.
2. Basic materials
Standard version:
carbon steel with grade determined by the client
3. Design
In standard version condensate recovery units are made as full packets ready for assembling on site (with full equipment).
Optional version
construction for work in Ex zone
construction without fittings (without Measurement and Control System and piping on the forcing pumps)
4. Characteristics
Condensate recovery units are used to receive and accumulate hot (max. 98?C) or cold condensate which flows through the pipelines from the heat receivers which are steam powered or from the steam tracing system of the processed pipelines. The condensate is then pumped via rotodynamic pumps from the tank to the place of secondary use. In standard the packet includes a condensate tank V-1 which is placed on a support frame K-1. Under the tank on the support frame there are condensate pumps P-1A/B (main and reserve) as well as piping for the suction and forcing pumps. On the tank there are 2 condensate inlet sockets. The tank has got a vent and overflow pipelines as well as a drain. On the tank and the piping there have been installed automatic control instruments and measuring instruments which allow the station to work automatically.
5. Requirements and testing
Depending on the type of the condensate recovery unit they are submitted to different requirements and subjected to different tests.
Condensate recovery units made in standard version are not submitted to UDT (Office of Technical Inspection).
6. Directions for ordering
To receive detailed information when making an enquiry it will be necessary to complete a data input card supplied by the manufacturer which will help us select and design the condensate recovery unit.
7. Additional information
This offer doesn't answer all the questions connected with the use of the condensate. It only presents constructional and operational questions about the condensate recovery unit as packet in an objective way. If you need to receive more precise information please contact our engineering and sales department. To start with you should fill in the "input data card" and send it to the manufacturer.
24 months warranty compulsory acc. to the conditions which are in the manufacturer's warranty card.
The manufacturer is able to undertake inspections and repairs of the fittings as well as replacement of the internal elements if required.
All the requirements concerning the quality and technical specifications of the fittings should be taken into consideration in your order. With the fittings we provide specification sheets (technical and quality) as follows: standard - conformity declaration, Installation, Operation and Maintenance Manual, at the client's request - certificate 2.2 or 3.1.
We reserve the right to introduce some technical changes without notice.
Steam tracers
The Central European climate imposes special requirements concerning the protection of industrial transferring appliances In chemical plants, refineries, petrochemical and other plants in order to protect them from low temperatures. This kind of protection is guaranteed by steam tracing system, which is based on the trace lines.
Inverted bucket steam traps The WZ steam traps are inverted bucket steam traps. They operate thanks to difference in displacement of the float which is filled with condensate or a mixture of steam and water.
Wedge gate valves Wedge gate valves Gate valves are designed for general use pipelines in industrial systems. They can be installed on pipelines In a vertical or horizontal position and operate only when fully open or closed. Medium can flow in both directions. Typically we produce gate valves with hand drive.