MANIFOLDS FOR STEAM DISTRIBUTION AND CONDENSATE COLLECTION
TYPE: RFM/ZFM
Tmax: 425 °C PN40/CLASS 300 ANSI DN15-50
Main dimensions
Click to zoom
1. Application range
Click to zoom
2. Basic materials PN40 Class 300
Body (fig., item 1)
made of forged steel: P250GH (1.0460) SA 105
made of stainless steel: X2CrNiMo17-12-2 (1.4404) SA 182 F316L
Seat (fig., item 2): X8CrNiS18-9 (1.4305) AISI303
Valve head (fig., item 3): X39CrMoS17
+ QT (1.4122+QT) AISI 420 RM
Sealing ring (fig., item 4): graphite graphite
Gland (fig., item 5): X8CrNiS18-9 (1.4305) AISI303
3. Design
Main connection, top and bottom:
- flanged, socket weld ends, butt weld ends
DN25 (1"), DN40 (1/2"), DN50 (2") acc. to DIN or ANSI
Side connections right and left:
- flanged, socket weld ends, butt weld ends
DN15 (?"), DN20(3/4"), DN25 (1") acc. to DIN or ANSI
4. Characteristics
This device can be used for steam distribution duty (RFM) as well as condensate collection duty (ZFM). It is usually used on long pipeline systems, installations and appliances with steam tracing systems where steam, water, oil, etc. are used as heating mediums. It is made of modules which are fitted with type head/seat stop valves. All the elements of these valves are hard sealed (metal/metal). Built in stop valves hardly need any servicing. They are characterised by their long life. When needed all the elements can be replaced without the ZFM being dismounted from the installation.
When used for steam distribution duty the medium (steam) is supplied from the top. To ensure distributor drainage it is necessary to install a steam trap in the bottom part of the manifold.
When used for condensate collection duty, the condensate is usually carried away from the top part of the manifold. It is recommended then to use a drain valve in its bottom part. To avoid water hammers, when the manifold is installed in the vertical position, it is recommended to install the manifolds in a special way with a built in pipe which will work as a compensator.
5. Requirements and testing
Depending on the type of device they are submitted to different requirements and subjected to different tests.
6. Directions for ordering
When giving your order you should supply the following information:
- medium,
- the maximum operating pressure,
- the maximum operating temperature,
- type and size of the connections (main and sides).
- number of branches
7. Additional information
- 24 months warranty compulsory acc. to the conditions which are in the manufacturer's warranty card.
- The manufacturer is able to undertake inspections and repairs of the fittings as well as replacement of the internal elements if required.
- All the requirements concerning the quality and technical specifications of the fittings should be taken into consideration in your order. With the fittings we provide specification sheets (technical and quality) as follows: standard - conformity declaration, Installation, Operation and Maintenance Manual, at the client's request - certificate 2.2 or 3.1.
We reserve the right to introduce some technical changes without notice.
|