← Back to publications
Valves and controlArticle

Hydropower valves: repair, replacement and fast opening

Refurbishing a hydropower plant requires valves that fit an existing site, often with little freedom to change the available space. Four examples show why seals and bodies matter alongside the practical task of moving and installing the equipment.

Handling a large gate valve during plant refurbishment.
Handling a large gate valve during plant refurbishment.

Straszyn and Łapino: when replacement is needed

At Straszyn, a DN1500 gate valve was installed in June 2011 to replace a cast-iron valve damaged by freezing. The account describes a forged and welded construction, an AUMA actuator and thermal protection. At Łapino, four DN1300 gate valves were replaced in December 2012 because refurbishment was not justified by their condition. Installation required an additional lifting arrangement suited to the site.

Bielkowo: refurbishment with limited access

The Bielkowo example concerns three DN1300 butterfly valves refurbished in 2011. Handling used rails and trolleys, and the sealing surfaces were repaired. Larger cracks were treated by cold stitching. The repair method and the logistics of removal were both central to the work.

Świnna Poręba: the bypass function

For Świnna Poręba, pneumatically actuated QUADAX valves were intended to open a turbine bypass rapidly and limit water hammer. The stated 0.6-second time belongs to the arrangement described. The project was still in progress in 2013; this describes a historical stage of the work.

Download publication

PDF · Polish · 2 pages · 0.15 MiB

Download full article PDF

Don’t lose steam!