ZAMKON / Technical knowledge

Technical publications

Valves, steam and condensate — technical articles, installation experience and company documents. Read online or download the full publication as a PDF.

19 documents

Company materialsBrochure

Steam losses in drainage systems mean real financial losses

Trap inspections help assess the financial effects of steam loss. Ultrasound and temperature measurements help identify faults, while example tables estimate annual losses. Applying these figures to a plant requires understanding the assumptions and resolving inconsistent labels. Historical values are not current energy prices.

PDF · Polish · 2 pages · 2.77 MiB

Valves and controlArticle

Cryogenic valves: shut-off tightness and stem sealing

Tight shut-off and control of leakage around the stem are separate requirements. QUADAX designs address thermal deformation, while an emissions test for a butadiene application demonstrates the importance of external leakage control. Assessing valves for demanding media requires more than checking the contact between the disc and seat.

PDF · Polish · 2 pages · 0.2 MiB

Valves and controlArticle

QUADAX at −196°C: design and a reported test

How can a metal seal remain flexible while handling mechanical loads? A four-offset butterfly valve and a DN600 test at −196°C illustrate these requirements. The operating principle must be distinguished from a specific test result, and a tightness claim considered together with its test conditions.

PDF · English · 1 pages · 0.12 MiB

Steam tracingArticle

Modern steam tracing: RFM and ZFM stations

How can the supply and drainage of many tracing lines be organised? RFM distribution, ZFM collection and modular stations with replaceable valve components provide a coordinated arrangement. Product temperature, steam conditions and condensate subcooling must be considered together, with service access and inspection as important as the heating itself.

PDF · Polish · 2 pages · 2.52 MiB

Steam tracingArticle

Steam tracing: loop routing and condensate collection

Steam flows from the distribution manifold through a tracer to the trap and condensate collection station. A simple diagram and installation photographs explain loop length, thermal expansion and drainage selection. Following the whole heating circuit makes it easier to consider routing together with access to the valves.

PDF · Polish · 2 pages · 0.6 MiB

Steam tracingArticle

Steam tracing systems: manifold selection and servicing

Modular stations organise drainage and allow servicing without dismantling the entire manifold. RFM/ZFM cooperation, subcooling adjustment and trap selection for the steam conditions help compare traditional and modular arrangements. Maintenance access should be considered during design.

PDF · Polish · 2 pages · 0.13 MiB

Steam and condensateArticle

Condensate in compressed air: drainage points and WSP operation

Compressing and cooling air releases water that must be removed from coolers, receivers and pipelines. The arrangements presented in 2001 include drainage with and without pressure equalisation, prevention of gas locking and suitable pipe gradients. A humidity graph and a historical WSP-2 datasheet help illustrate the operating principle of the system.

PDF · Polish · 7 pages · 1.24 MiB

Research and designArticle

Research and Development Centre: measuring valve characteristics

The research facilities support measurements of flow, Kv/Kvs coefficients and valve behaviour at different openings. A photograph of the HPE8 installation illustrates the measurement setting. Measurement results support design development. The investment stage presented here is historical.

PDF · Polish · 2 pages · 2.2 MiB

Company materialsBrochure

ZAMKON Polish brochure: valves, systems and services

This twenty-page brochure presents steam traps, valves, steam and condensate assemblies and engineering services. It includes project photographs, research facilities and the training room. The equipment range presented is historical. Specific parameters and the status of supporting documents should be checked in the relevant datasheets and during selection.

PDF · Polish · 20 pages · 12.23 MiB

Company materialsBrochure

ZAMKON English brochure: equipment and engineering projects

The English brochure presents traps and valves alongside condensate recovery, steam tracing and engineering services. Its twenty pages combine equipment illustrations, installation photographs and training information. The ranges and descriptions in this version are not identical in every detail to the separate Polish brochure.

PDF · English · 20 pages · 7.54 MiB

Selection and maintenanceArticle

Valve selection and pipeline cleanliness: how damage develops

Correct selection does not protect a valve from debris left in an installation. Photographs of damaged seals, contaminated strainers and service tests show why selection criteria must be considered together with storage, pipeline preparation and post-repair acceptance. An oxygen-service example illustrates why a special cleanliness regime must be maintained throughout the work.

PDF · Polish · 13 pages · 1.83 MiB

Company materialsCatalogue

ZAMKON valve catalogue: a guide to datasheets and tables

The 119-page catalogue brings together special versions, material tables, steam data and datasheets for traps, butterfly valves, gate valves, other valves and strainers. It also includes actuator-selection tables. Selection requires dimensions, materials, curves and application limits to be considered together. The sheets come from different revisions and require individual checks for currency.

PDF · Polish · 119 pages · 19.95 MiB

Research and designArticle

A quarter-turn indicator on a non-rising-stem gate valve

A gate valve takes multiple turns, while its position indicator needs quarter-turn movement. The mechanism presented on 22 April 2022 connects the two motions. A photograph and four assembly views explain the nut, guide and lever arrangement and how the valve’s end positions are indicated.

PDF · Polish · 2 pages · 0.57 MiB

Steam and condensateArticle

Steam trap monitoring: finding losses between inspections

A faulty trap can leak live steam or hold back condensate. Wireless monitoring combines acoustic and temperature measurements with PlantWeb Insight. Continuous observation complements periodic inspections, and a change in trap operation matters to both energy use and steam-consuming equipment.

PDF · Polish · 2 pages · 0.46 MiB

Valves and controlArticle

Cavitation control in a butterfly control valve

Perforated components beside the disc change the pressure-drop distribution at partial opening. Their action affects control range and fully open operation; a COAX-LT arrangement supports very small flows. Flow illustrations help distinguish simple throttling from deliberately shaping the operating conditions within the valve.

PDF · Polish · 3 pages · 0.83 MiB

Steam tracingArticle

Steam tracing design: from heat losses to manifolds

Product temperature, ambient conditions and insulation determine the heating duty. The design approach presented in 2016 follows the process from the heat balance through tracing loops to drainage and RFM/ZFM manifolds. Loop identification and prefabrication also help with installation, later inspections and day-to-day operation.

PDF · English · 2 pages · 0.86 MiB

Steam and condensateArticle

Condensate and water hammer: SPZ-12 DUO and TUW

Moisture in steam and sudden pressure changes affect an installation in different ways. The SPZ-12 DUO separator and TUW damper perform separate duties in protecting the installation. Cutaway illustrations help show condensate separation and buffering. The figures for these historical versions must be considered together with their limitations.

PDF · Polish · 1 pages · 0.12 MiB

Valves and controlArticle

Hydropower valves: repair, replacement and fast opening

Straszyn, Bielkowo, Łapino and Świnna Poręba illustrate different challenges in hydropower valve work. Examples presented in December 2013 include large gate valves, butterfly valve refurbishment and a fast-opening bypass. Relating equipment condition to installation access, handling and service requirements helps inform the decision to repair or replace.

PDF · Polish · 2 pages · 0.15 MiB

Valves and controlArticle

The QUADAX fourth offset: geometry, sealing and control

A fourth offset changes butterfly valve geometry so that sealing contact occurs near the end of closure. Comparing triple- and four-offset designs, seal-ring options and flow characteristics connects component shape with operation. The parameters and approvals concern historical versions.

PDF · Polish · 2 pages · 0.48 MiB

Company presentation

ZAMKON presentation

Explore ZAMKON’s equipment and capabilities in our English presentation.

Download presentation EN PPSX · 32 MiB

Don’t lose steam!

Let’s discuss your installation